flat roof decking constructions

Occasionally, however, flat roofs are designed to collect water in a pool, usually for aesthetic purposes, or for rainwater buffering. Traditionally most flat roofs in the western world make use of tar or asphalt more usually felt paper applied over roof decking to keep a building watertight.

Shed DormerFlat Roof ShedFlat Roof ConstructionRoof DeckArticle HtmlTraditional HomesGaragesShelterCurb Appeal. Building a Flat Roof Right - Traditional homes often have sections of flat roof—over shed dormers, above porches and garages, and on balconies. And their horizontal lines abound in the West and in 

Construction studies drawing detail showing how to draw a flat roof warm deck construction detail to a scale of 1:10 with a short introduction highlighting t

When waterproofing a walkable roof deck, there are a number of important principles to consider in determining the ultimate performance of not only the waterproof decking membranes must comply with Canada Mortgage and Housing Corporation's (CMHC's) Canadian Construction Materials Centre 

We would recommended the use of double entry type drains so that the water can drain at surface and deck level. This is a similar construction to the warm roof as insulating above the deck ensures that the structure of the building is warm. The most common deck types used in flat roof constructions are concrete, timber and 

In terms of the thermal design of a flat roof, what are the options and the best practices of flat roof build ups? The recognised flat roof build ups for best design practices are: Cold Roof; Warm Roof; Inverted Roof. In the case of a flat roof, insulation is usually either a rigid board above the deck, or a mineral 

In the case of a flat roof, moist warm air rises from the room below into the roofing fabric where, it risks condensing on the underside of the roof decking water-proof in traditional flat roof construction, the moist air is prevented from penetrating the roof fabric through the use of a vapour control layer at ceiling level.

NHBC recommend that this type of roof be considered as the standard form of construction. Types of Warm deck roof. There are two forms of warm deck roof: Sandwich; Inverted. Warm Deck: Sandwich Roof. The sandwich warm deck roof is the most common type of flat roof. The insulation is placed below the waterproof 

Flat Roof ConstructionWarm RoofFlat Roof DesignDormer IdeasRoof TypesRoof PlanRoof IdeasGarage IdeasHard To. Flat roofs have been a daunting task for contractors and homeowners alike since they were invented. They are hard to waterproof, hard to maintain, and hard to insulate. For today's purposes, we will stick 

Flat Roof Insulation >>. Flat Roof - Deck. Deck. A 'deck' is the structural substrate of a flat roof and should be capable of supporting the static and dynamic design loads as well as any loads occurring during construction from machinery and plant. The deck should be of adequate strength and stiffness to ensure structural 

There are two common forms of construction for flat roofs: Warm deck (sandwich), or. Cold deck. Warm Deck Roof. With this type of roof the insulation is placed above the roof deck but below the weatherproofing. There should be no insulation below the deck and no ventilation is required. Some forms of roof decking may 

Warm Deck Roof Designs for EPDM. The warm deck roof design is the modern construction method for flat roofs and is preferred wherever this option is possible. Solid (Closed Cell) roof insulation such as Kingspan or Celotex is placed on top of the roof deck rather than in between the rafters. A vapour barrier needs to be 

The ceiling joists are used as the platform for the roof coverings. The fall of the roof is achieved by using firring pieces, with a fall of 1 in 40. The flat roof shown above shows Warm Deck Roof Construction. In this type of construction the insulation is placed below the waterproof covering and on top of the roof deck and vapour 

A hybrid cold flat roof is one where at least 2 3rds of the insulation is above the roof deck or joists, however this is a general guide and could change depending upon the building use, location and humidity class. We would recommend a condensation risk analysis be carried out on every hybrid flat roof construction to 

The regulations were changed to implement the EU Energy Performance of Buildings Directive (EPBD), which aims to reduce energy use in domestic buildings by 20% compared to the 2002 regulations. There are essentially two designs used in the construction of a flat roof to include insulation. Cold deck (fig 1). This is the 

WARM ROOF. This type of construction has the insulation above the roof deck, thus keeping the deck 'WARM'. This is usually the most satisfactory construction for domestic properties as it avoids the need for ventilation of the roof structure. The membrane is then attached to the insulation. A typical warm roof is shown in the 

Product Details